Support 4D probe; figure out the probe by way of the ID code; switch the 4D push sign via the electrical relay to produce the 4D probe operate Commonly. 4.2.two Most important board The principle board might be divided into two parts: front-conclude of the primary board and again-stop of the primary board.
Cookie penting untuk memfungsikan situs dengan semestinya. Untuk meningkatkan pengalaman Anda, kami menggunakan cookie untuk mengingat detail login Anda dan menyediakan login aman, mengumpulkan statistik untuk mengoptimalkan fungsionalitas situs, dan menyediakan konten yang disesuaikan dengan minat Anda.
Be aware: To the observe, the brightness adjustment comes just before contrast. Immediately after readjusting the keep track of’s contrast and brightness, adjust all preset and peripheral settings.
Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.
Cut off cable ties connecting the main unit within the Exhibit by diagonal slicing pliers, then pull out the corresponding cable plugs.
When you quit the scanning and also the graphic capture, you'll want to electricity from the system and disconnect the technique through the AC electrical power provide, then pull out AC power cables. Web site 109: Battery Connecting Board
The chapter provides the method to confirm main function and general performance of solution. This is often only useful for reference, not preventive execution. Operate examining and testing of the part shall be carried out by Mindray support engineers plus the user collectively. Page sixty six: Typical Exam
Test Remember my selection and click Okay inside the dialog box earlier mentioned to hitch ordeals a lot quicker in the future! Many thanks for visiting Roblox
Permits utilization of numerous scanned angles to sort an individual graphic, leading to Increased contrast resolution and improved visualization
5.two.three Geometric positioning precision Longitudinal geometric positioning precision Take a look at Step: Do adjustments as the way in testing the most depth. History the space by 20mm Each and every phase on the longitudinal targets line using the measurement caliper; Choose the value with the greatest error (to 20mm), estimate the precision utilizing the components down below The measurement caliper ought to be positioned on the upper edge of the goal, Be aware:... Website page 79 Transverse geometric positioning precision Take a look at Action: Go over the scan surface area on the phantom with h2o or pair gel, Carefully Get hold of the probe With all the scan floor Regulate the depth, producing the transverse targets for being displayed inside the picture. Adjust the focus position to be posited beside the transverse targets (the common is just not crystal clear) Adjust parameters like get, TGC, generating Every transverse targets to generally be Plainly shown. Web site 80 five.5.2.4 Blackout Spot Examination Step: Address the scan surface area of the phantom with drinking water or pair gel, gently contact the probe Along with the scan surface Dp50rb login area Regulate the depth at a decrease value, and set the main focus at the closest place to the scan surface area. Minimize the value of parameters like AP, Achieve till the qualifications noise just is usually noticed. Website page 81: Program Upgrade And Upkeep
The DP-fifty Professional is undoubtedly an impressive, large-efficiency Ultrasound Process engineered to assist you obtain the insights you require. The Procedure’s highly effective motor and substantial-velocity processing give outstanding graphic excellent and a whole info management Remedy.
Uncover far better diagnostic info through extended see in the anatomical composition on all linear probes
Effectiveness Test 5.5.one Check Approach Resolution Detection depth Geometric Placement Precision Blackout region test Document the Test illustrations or photos five.five.2 Test Written content The picture used here is only for reference, stick with the graphic outcome in the real Notice: predicament. Demands: Exhibit: established the contrast and brightness within the clinical application worth (or maybe the default status) Operation natural environment: dim area, simulating the scientific software surroundings. Site seventy six In ailment that the transverse resolution testing targets are horizontally displayed, file the small length of two targets which might be clearly recognized. Repeat the operation previously mentioned to the transverse resolution testing targets at other depths. As shown in figure beneath. Axial resolution ... Webpage 77 When using the convex probe, hold the transverse resolution testing targets to NOTE: be shown close to the midline. When employing a linear probe with steer purpose, never turn on the steer functionality when conduct the transverse resolution take a look at. Zoom inside the area in which the targets Found if necessary. The diameter in the goal point at a particular depth is equal for the transverse resolution on the depth. Webpage 78 5.
Immediately after changing the CPU module, key file has to be produced Once more based on the new MAC tackle and published into HDD of your equipment. Or else, the configuration function of the products will probably be lost. Right after taking away the CPU module, Clear away panhead screws with washers (twelve M3X6) fastened on the most crucial device box, you can take from the board. Web page 118 Determine eight-29 Disassemble the Control Panel Assembly (1) Keep the higher edge of user interface assembly, and open up the control panel. Determine 8-thirty Disassemble the User interface Assembly (2) Following removing one countersunk head self-tapping screw PT3X10 mounted within the control panel and consider out the plug of your keyboard and the leading unit connecting cables, you could take away the control panel assembly.
Return for the program preset interface. The option status modifications into Uninstalled. The uninstalling function is exclusive to interior buyers.